Human study PLS-00174

Thymosin beta 4 ophthalmic solution for dry eye: a randomized, placebo-controlled, Phase II clinical trial conducted using the controlled adverse environment (CAE™) model.

Randomized controlled trial · Not reported participants enrolled

Version 1 · published November 8, 2026 · evidence through November 8, 2026 · research snapshot 2026.1.1 · methodology ev-1 · Automated assessment by AI (claude-opus-5-5 and claude-sonnet-5-5), not reviewed by a person.

Only the abstract was available. Essential methods may be missing, which limits what can be judged.

Reports of this study

Every publication, registration and abstract describing this one study. Participants are counted once.

  • Thymosin beta 4 ophthalmic solution for dry eye: a randomized, placebo-controlled, Phase II clinical trial conducted using the controlled adverse environment (CAE™) model.primary · Clinical ophthalmology (Auckland, N.Z.) · 2015-05-20 · PMID 26056426 · DOI

Design and participants

Design
Randomized controlled trial
Population
Subjects with moderate to severe dry eye who qualified for a controlled adverse environment (CAE) challenge model study
Conditions
Dry eye disease (moderate to severe)
Setting
Single-center study using the controlled adverse environment (CAE) model
Planned enrollment (registry)
Not reported
Enrolled
Not reported
Randomized
72
Completed follow-up
Not reported
Funding
Not stated in the record
Authors’ conflicts
Not stated in the record

Intervention and comparator

What each group received. Related peptides, analogs and combinations are never treated as the compound itself.

  • Tβ4 ophthalmic solution (intervention) · thymosin-beta-4 · Thymosin beta 4 ophthalmic solution (RGN-259) · topical ophthalmic · 28 days of treatment within a 32-day study period · Not reported assigned
  • Placebo (comparator) · Placebo ophthalmic treatment · placebo · topical ophthalmic · 28 days of treatment within a 32-day study period · Not reported assigned

What the authors reported

As stated in the sources. This is the authors’ account, not Peptide Library’s assessment.

Ocular discomfort score

primary outcome · patient-important · Visit 5, day 29 · Ocular discomfort score

  • Tβ4 ophthalmic solution vs Placebo: narrative — No significant difference between treatment and control groups at visit 5

Inferior corneal staining

primary outcome · surrogate · Visit 5, day 29 · Inferior corneal staining score

  • Tβ4 ophthalmic solution vs Placebo: narrative — No significant difference between treatment and control groups at visit 5

Ocular discomfort during CAE challenge

secondary outcome · patient-important · Day 28 CAE visit · Discomfort scores in the controlled adverse environment

  • Tβ4 ophthalmic solution vs Placebo: other, p = 0.0244 — Discomfort scores in the CAE were reduced by 27% with Tβ4 compared with placebo

Central corneal staining

secondary outcome · surrogate · Not stated in abstract · Central corneal staining score

  • Tβ4 ophthalmic solution vs Placebo: narrative, p = 0.0075 — Statistically significant improvement in central corneal staining versus control

Superior corneal staining

secondary outcome · surrogate · Not stated in abstract · Superior corneal staining score

  • Tβ4 ophthalmic solution vs Placebo: narrative, p = 0.021 — Statistically significant improvement in superior corneal staining versus control

Conjunctival staining

secondary outcome · surrogate · Not stated · Conjunctival staining score

  • No results reported.

Conjunctival redness

secondary outcome · surrogate · Not stated · Conjunctival redness score

  • No results reported.

Tear film break-up time

secondary outcome · surrogate · Not stated · Tear film break-up time

  • No results reported.

Daily symptom scores

secondary outcome · patient-important · Throughout study · Daily symptom scores recorded over the course of the study

  • No results reported.

Adverse events

secondary outcome · safety · Over the 32-day study period · Adverse events, plus safety measures including visual acuity, slit-lamp examination, intraocular pressure, dilated funduscopy and corneal sensitivity

  • Tβ4 ophthalmic solution vs Placebo: narrative — No adverse events were observed or reported by any subject

Adverse events

None reported. That is not evidence of safety.

Monitoring: Visual acuity, slit-lamp evaluation, conjunctival redness, tear film break-up time, intraocular pressure, dilated funduscopy and corneal sensitivity were assessed across six visits over 32 days.

The authors concluded (paraphrased): The authors concluded that topical Tβ4 is effective for relieving signs and symptoms of dry eye and has a large safety window, with no adverse events reported. This was despite both primary endpoints showing no significant difference.

Peptide Library’s assessment

An automated assessment, made by AI separately from the authors’ conclusions and not reviewed by a person. How risk of bias is assessed.

Limitations

  • selective reporting: Both primary endpoints were null, yet the conclusion rests on selected significant secondary endpoints, with no stated adjustment for multiplicity.
  • small or imprecise: Only 72 subjects were randomized at a single center, and no effect sizes with confidence intervals are reported in the abstract.
  • short follow up: Treatment lasted 28 days within a 32-day study, so durability of effect and longer-term safety are unknown.
  • other: The controlled adverse environment challenge model is an artificial setting that may not reflect everyday dry eye symptoms.
  • abstract only: Only the abstract was available, so randomization methods, attrition, group sizes and analysis populations cannot be verified.
  • funding or conflicts: Funding and conflicts are not reported in the record, although the product code RGN-259 suggests a commercial sponsor.
  • inappropriate endpoint: Both primary endpoints (discomfort and inferior corneal staining at day 29) showed no significant difference; the benefits are in secondary endpoints, and multiplicity is not addressed.

Ocular discomfort score: Some concerns (Cochrane RoB 2)

Risk of bias in one result of a randomized trial, judged in five domains.

Domain judgments
Randomization processSome concernsThe abstract states 1:1 randomization but gives no details of sequence generation, allocation concealment or baseline balance.
Deviations from intended interventionsSome concernsDouble-masked and placebo-controlled, but adherence and the analysis population are not described in the abstract.
Missing outcome dataSome concernsThe abstract reports no numbers completing or analyzed, so attrition cannot be assessed.
Measurement of the outcomeLow risk of biasThis subjective discomfort score was collected under double masking with a placebo comparator.
Selection of the reported resultSome concernsThis prespecified primary endpoint is reported only narratively as non-significant, with no numeric estimate.

Several domains have some concerns because only the abstract was available and reporting is incomplete.

Version 1 · published November 8, 2026 · evidence through November 8, 2026 · research snapshot 2026.1.1 · methodology ev-1 · RoB 2 (2019-08-22) · Automated assessment by AI (claude-opus-5-5 and claude-sonnet-5-5), not reviewed by a person.

Inferior corneal staining: Some concerns (Cochrane RoB 2)

Risk of bias in one result of a randomized trial, judged in five domains.

Domain judgments
Randomization processSome concernsRandomization is stated, but methods and allocation concealment are not reported in the abstract.
Deviations from intended interventionsSome concernsDouble-masked design, but no information on adherence or the analysis set is given in the abstract.
Missing outcome dataSome concernsCompletion and analyzed numbers are not given in the abstract.
Measurement of the outcomeLow risk of biasStaining was assessed in a double-masked, placebo-controlled study.
Selection of the reported resultSome concernsThis primary endpoint is reported only as non-significant, without numeric results.

There are some concerns from unreported randomization details, attrition and numeric results.

Version 1 · published November 8, 2026 · evidence through November 8, 2026 · research snapshot 2026.1.1 · methodology ev-1 · RoB 2 (2019-08-22) · Automated assessment by AI (claude-opus-5-5 and claude-sonnet-5-5), not reviewed by a person.

Ocular discomfort during CAE challenge: High risk of bias (Cochrane RoB 2)

Risk of bias in one result of a randomized trial, judged in five domains.

Domain judgments
Randomization processSome concernsThe randomization process is not described beyond 1:1 allocation in the abstract.
Deviations from intended interventionsSome concernsDouble-masked, but adherence and analysis approach are not reported in the abstract.
Missing outcome dataSome concernsAttrition and analyzed numbers are not reported in the abstract.
Measurement of the outcomeLow risk of biasDiscomfort was rated by masked participants in a placebo-controlled design.
Selection of the reported resultHigh risk of biasThis is one significant secondary endpoint chosen from many, highlighted after null primary endpoints, with no stated multiplicity control.

High risk of selective reporting of a favourable secondary result.

Version 1 · published November 8, 2026 · evidence through November 8, 2026 · research snapshot 2026.1.1 · methodology ev-1 · RoB 2 (2019-08-22) · Automated assessment by AI (claude-opus-5-5 and claude-sonnet-5-5), not reviewed by a person.

Central corneal staining: High risk of bias (Cochrane RoB 2)

Risk of bias in one result of a randomized trial, judged in five domains.

Domain judgments
Randomization processSome concernsNo sequence generation or concealment details are given in the abstract.
Deviations from intended interventionsSome concernsDouble-masked, but deviations and the analysis set are not described.
Missing outcome dataSome concernsThe number analyzed and dropouts are not stated in the abstract.
Measurement of the outcomeLow risk of biasCorneal staining was graded under double masking with a placebo control.
Selection of the reported resultHigh risk of biasThis significant secondary endpoint is emphasized among many endpoints while the primary endpoints were null, without multiplicity adjustment.

High risk of bias from selection of the reported result among many secondary endpoints.

Version 1 · published November 8, 2026 · evidence through November 8, 2026 · research snapshot 2026.1.1 · methodology ev-1 · RoB 2 (2019-08-22) · Automated assessment by AI (claude-opus-5-5 and claude-sonnet-5-5), not reviewed by a person.

Superior corneal staining: High risk of bias (Cochrane RoB 2)

Risk of bias in one result of a randomized trial, judged in five domains.

Domain judgments
Randomization processSome concernsThe randomization method is not reported in the abstract.
Deviations from intended interventionsSome concernsAdherence and the analysis population are not reported, although the trial was double-masked.
Missing outcome dataSome concernsNo information on completers or missing outcome data is given in the abstract.
Measurement of the outcomeLow risk of biasStaining was assessed in a double-masked, placebo-controlled trial.
Selection of the reported resultHigh risk of biasThis favourable secondary result is highlighted among many endpoints after null primary results, with no multiplicity control stated.

High risk from selective emphasis of secondary endpoints.

Version 1 · published November 8, 2026 · evidence through November 8, 2026 · research snapshot 2026.1.1 · methodology ev-1 · RoB 2 (2019-08-22) · Automated assessment by AI (claude-opus-5-5 and claude-sonnet-5-5), not reviewed by a person.

Adverse events: Some concerns (Cochrane RoB 2)

Risk of bias in one result of a randomized trial, judged in five domains.

Domain judgments
Randomization processSome concernsRandomization details are not reported in the abstract.
Deviations from intended interventionsSome concernsNo information on adherence or the analysis set for safety is given in the abstract.
Missing outcome dataSome concernsThe number of subjects followed for safety is not reported in the abstract.
Measurement of the outcomeSome concernsThe method of adverse event ascertainment and its definitions are not described in the abstract.
Selection of the reported resultSome concernsAdverse events are reported only as none observed, with no per-arm breakdown.

Safety reporting is sparse and the methods are unclear from the abstract.

Version 1 · published November 8, 2026 · evidence through November 8, 2026 · research snapshot 2026.1.1 · methodology ev-1 · RoB 2 (2019-08-22) · Automated assessment by AI (claude-opus-5-5 and claude-sonnet-5-5), not reviewed by a person.

Claims this study informs

  • Very low certainty Ocular discomfort and corneal staining
  • Insufficient information to assess Adverse events, serious adverse events and discontinuations

Where each value comes from

  • adverse_events: PMID 26056426, abstract (Results, sentence 5) · extracted by AI (automated, not verified by a person) · abstract only
  • arms: PMID 26056426, abstract (Methods, sentences 1-2) · extracted by AI (automated, not verified by a person) · abstract only
  • author_conclusion: PMID 26056426, abstract (Conclusion, sentences 1-2) · extracted by AI (automated, not verified by a person) · abstract only
  • design: PMID 26056426, abstract (Methods, sentence 1) · extracted by AI (automated, not verified by a person) · abstract only
  • limitations: PMID 26056426, abstract (Results, sentences 1-2) · extracted by AI (automated, not verified by a person) · abstract only
  • outcomes: PMID 26056426, abstract (Methods, sentences 3-5) · extracted by AI (automated, not verified by a person) · abstract only
  • participants: PMID 26056426, abstract (Methods, sentence 1) · extracted by AI (automated, not verified by a person) · abstract only
  • population: PMID 26056426, abstract (Background, sentence 1) · extracted by AI (automated, not verified by a person) · abstract only
  • results: PMID 26056426, abstract (Results, sentences 1-4) · extracted by AI (automated, not verified by a person) · abstract only
  • Version 1 · published November 8, 2026 · evidence through November 8, 2026 · research snapshot 2026.1.1 · methodology ev-1 · Automated assessment by AI (claude-opus-5-5 and claude-sonnet-5-5), not reviewed by a person.

These assessments describe published research. Records marked automated were produced by AI under the published methodology and have not been reviewed by a person; they can contain errors. None of this is medical advice, not a statement about any product’s safety for human use, and not a regulatory approval. Peptide Library’s vendor and partner relationships play no part in them (editorial independence).